Electronic Shut-Off Valve

Distinguishing Features
  • Conserves water
  • Positive shut-off
  • Compact design
  • Plastic valve body
  • Low power
  • Cool running
  • Hermetically protected electronics for long life

Technical Specifications

WETTED MATERIALS OF CONSTRUCTION: Polypropylene, EPDM, 300 and 400 Series Stainless Steel.
POWER REQUIREMENTS: ESO 460: 24 VAC, 50/60 Hz, 150 mA; ESO DC-100: 24 VAC or VDC, 120 mA
INLET PRESSURE/ORIFICE: ESO 460: 45 psi max. with .093" dia. orifice; ESO 460: 100 psi max. with .062" dia. orifice; ESO DC-100: 100 psi max. with .093" dia. orifice.
FITTINGS: 1/4" black inlet and 1/4" white outlet Jaco fittings as standard. 1/4" grey John Guest fittings optionally available at slight cost premium.


Leak Detector Sensor Valve

Distinguishing Features
  • Protection from leaks
  • Integrated sensing circuit
  • Hermetically protected for reliability
  • 1 year warranty
  • Optional latched or unlatched outlet

Technical Specifications

WETTED MATERIALS OF CONSTRUCTION: Polypropylene, EPDM, 300 and 400 Series Stainless Steel.
POWER REQUIREMENTS: LDU 900: 24 VAC, 50/60 Hz, 157 mA; Switched output power-24 VAC, 1 amp.; LDS 700: 24 VAC, 50/60 Hz, 30 mA.
INLET PRESSURE/ORIFICE: LDS 800: 100 psi max./.093" orifice.
FITTINGS: 1/4" black inlet and 1/4" white outlet Jaco fittings as standard. 1/4" grey John Guest fittings optionally available at slight cost premium.
PROBE SENSITIVITY: 250 kilo-ohm-Stainless Steel Position: Closed Water Temperature: 180 degree F maximum.


Auto-Flush Timer Valve

Distinguishing Features
  • Reduces "brine to product" ratio
  • Improves system "TDS" rejection rate
  • Extends membrane life
  • Hermetically protected electronics for long life

One of the challenges addressed by Aquatec's Engineering staff was the development of a device that would assist the R.O. membrane to perform with maximum efficiency for longer time periods. Most designers recommend that a R.O. system be flushed on a regular basis. Aquatec's AFR 600 series Auto-Flush valve provides this flush. In addition, designers can reduce the "brine to product" ratio, especially in low "TDS" applications, while maintaining or improving system "TDS" rejection rate and extending membrane, sediment and carbon filter life.
Upon system start-up and every hour thereafter, the 24 VAC normally closed solenoid valve automatically "power-flushes" the membrane at full pump flow, or full line pressure in unboosted systems, for 18 seconds every hour. Turbulent water action scrubs organic and inorganic contaminants from the membrane surface, extending membrane life and efficiency.
The "power flush" occurs only while the system is in the water making mode. The flush cycle is reset automatically when the R.O. system repeats the "water making" mode after the "full tank shut-down" mode. Water which has been standing idle in the membrane module for an extended period, is purged to the drain. The AFR 600 requires its own transformer or can be powered by the pump transformer.
The valve has a built in, self cleaning, flow restrictor which allows controlled flow to drain when the valve is in the de-activated (closed) state. Flow restrictors from 300 to 700 mL/min. are available.
Contact factory for higher flow rates.


TLC 900 Tank Level Control Switch Valve

Distinguishing Features
  • Conserves water
  • Separately adjustable on and off levels
  • Positive level control and water Shut-off
  • Conserves energy
  • Extends system component life
  • Hermetically protected electronics for long life

Technical Specifications

WETTED MATERIALS OF CONSTRUCTION: Polypropylene, EPDM, 300 and 400 Series Stainless Steel.
POWER REQUIREMENTS: 24 VAC, 50/60 Hz, 130 mA.
SWITCHED OUTPUT POWER: 24 VAC, 1 amp.
INLET PRESSURE/ORIFICE: 100 psi max./.093" diameter orifice.
FITTINGS: 1/4" black inlet and 1/4" white outlet Jaco fittings as standard. 1/4" grey John Guest fittings optionally available at slight cost premium.
SENSORS/SENSITIVITY: Stainless Steel; up to 250 kilo-ohms for water greater than 3 ppm TDS.